Zetron Model 37 Max Manual

admin

View and Download ZETRON 025-9581M installation and maintenance manual online. Fire Station Alerting System. 025-9581M Security System pdf manual download.

  • Up one level (Moto index) Back to Home : The Motorola MaxTrac, Radius, GM300, DeskTrac, GR-series Index page Maintained By Robert Meister WA1MIK This page has.
  • Since 1965, Puget Sound Instrument has been providing customer the best prices and selection of Marine, Two-Way Radio and Surveillance Products. Use this page to find.

ZETRON 0. 25- 9. 58. M INSTALLATION AND MAINTENANCE MANUAL Pdf Download. Fire Station Alerting System Installation and Maintenance 0. M.. Zetron Products or Zetron Accessories or refund the purchase price, at Zetron's option, after return of such items by buyer to Zetron. Shipment shall be paid for by the buyer. No credit shall be allowed for work performed by the buyer.

Regulatory Compliance Information on Disposal of Old Electrical and Electronic Equipment and Batteries (applicable for EU countries that have adopted separate waste collection systems) Products and batteries with the symbol (crossed- out wheeled bin) cannot be disposed as household waste. Old electrical and electronic equipment and batteries should be recycled at a facility capable of handling these items and their waste byproducts. Warning! For your safety and the protection of the equipment, observe these STOP precautions when installing or servicing Zetron equipment: . M.. System Overview Introduction The Zetron IP Fire Station Alerting system (IP FSA) has been specifically designed to speed the dispatch of emergency vehicles, to aid in tracking their status, and to provide remote control and sense capability at each fire station. This system is ideal for any municipality that has IP links between its central communications center and its fire stations. This computer should not be running any third- party software or other Zetron software that is not related to FSA. Using the Vo. IP Gateway approach reduces the demands on the radio channels in use and prevents fire station alerts from being delayed by other radio traffic on the repeater.

For over 30 years, Zetron has been designing, developing, manufacturing and implementing mission-critical communications solutions for public safety, transportation.

Figure 2 provides an example of the basic system when the Vo. IP Intercom is used. M.. Overall System Operation Figure 2: Basic IP FSA System Using Vo. IP Gateway FSA Console running on a Dispatch position Voice audio for station alerts and talkback FSA alerting and status traffic DISPATCH CENTER BACK ROOM EQUIPMENT Dispatch Channel Card Rack with Audio Channel Cards Voice Audio IP Network.. If CAD is present, it can serve as the primary user interface by communicating commands to the FSA Server. To accomplish this, the CAD system will use either the existing Model 2.

CAD interface protocol or Zetron’s new XML- based protocol. IP FSA Console Functions have been played at the station), it signals the originating console position to go ahead and transmit any additional verbal announcement related to the alert. The voice audio is transmitted to the fire stations either by radio or by means of a Vo. IP intercom that uses the same IP network as the FSA Server. I/O window. Allocation of units from a single station (as shown in Figure 5) provides an alternate method for populating the I/O window . M.. What About CAD Systems?

Figure 5: IP FSA Console Window with Station I/O Open What About CAD Systems? If the dispatch center is already using a CAD system, then it is likely that the control functions for the FSA system will be integrated into the CAD system rather than setting up two console systems at each operator position. In a typical scenario, the Station Transponder Unit unmutes the station PA and plays the alert tones associated with the station or unit being alerted. If any relays have been programmed to accompany the alert, they will be energized as well. M.. Station Transponder Unit Functions The Station Transponder Unit keeps the PA open after it plays the alert tones and signals the IP FSA Server that the PA is available for a voice announcement. The current status of units is indicated on the front panel of Station Transponder Units with a column of LEDs for each unit.

When configured as Trunking interface, the Station Transponder Unit interprets the COR input as an “OK to transmit” signal rather than a “channel is busy” signal. Along with these special hardware circuits, there are a number of user- configurable software parameters for setting up and optimizing this interface.

M.. Station Transponder Unit Functions PA Control The Station Transponder Unit has two dedicated relays for controlling a Fire Station PA system. They are used to enable the PA system either when commanded to do so by the FSA Server, or locally using the handset in the Station Transponder Unit. The Station Transponder Unit typically uses the PA to play alert tones and dispatcher messages. Audio Dispatch Console) equipment with which the FSA system is installed in parallel; no sound card or motherboard audio capability is required for an FSA Console position.

If the Vo. IP Intercom option is used, then a Zetron- supplied sound card is required. Serial Port.. Specifications IP Network Functional Requirements Item Description IP Address FSA Server and Vo. IP Server = Static Assignment Station Transponder Unit and Vo.

IP Intercom = Static FSA Console = Uses host computer address assignment or static Packet Type FSA Alerting = uses TCP packets only Used Vo. IP Audio = TCP for incoming calls, UDP to broadcast outgoing calls Network.. M.. Overview Planning the System Overview This chapter is composed of several sections of rather general information and advice. It is intended to aid you in working up a plan for the installation of your system and to remind you of the various types of information you will need to collect and decisions that will need to be made in order to create a working system.

Subnet Mask. The Station Transponder Units will also need to be given the Gateway address that the router uses when it passes packets out of its local subnet to the subnet on which the server resides. M.. System Layout Figure 8: A Medium System Involving a Subnet Console #2 Console #1 Ethernet LAN Switch Local network FSA Server Ethernet Router Subnet connecting fire stations.

IP Station IP Station IP Station Unit #1 Unit #2 Unit #3 Figure 9 shows the case of a very large system composed of multiple subnets. Router FSA Server Ethernet Router Subnet connecting fire stations. IP Station IP Station IP Station Unit #1 Unit #2 Unit #3 Ethernet Router Subnet connecting fire stations. IP Station IP Station IP Station Unit #4 Unit #6 Unit #5 0. M.. Collecting and Assigning IP Information Collecting and Assigning IP Information There are a number of pieces of information that are helpful to have “in hand” prior to starting the installation of software components and network hardware that make up an IP FSA system.

Planning the System Default IP Addresses IP equipment from Zetron will typically be configured with an initial IP address. The following list identifies factory default IP addresses: . Free Installation Of Audio Output Device. The license key is based on the hardware ID number for the Network Interface Card (NIC) present (or possibly the hard drive the application has been installed on, if no NIC is present). Getting License Files To obtain a valid license for a Zetron application, you need to contact Zetron and provide specific information about the computer(s) on which the application has been installed. This information can be obtained as follows. This alternative method is useful if you don’t have the FSA CD with you to run License Manager. Once you receive the email back from Zetron, save the attached license files to a portable data device.

Insert the portable data device into the PC for which the files are intended. Planning the System crash or disk file corruption, the license files will be required in order to restore Fire Station Alerting.

M.. Overview Creating Console Positions Overview This chapter covers the installation of the FSA Console application onto the computers that are used in the dispatch center to create individual operator positions. It covers the installation of the console application and the loading of the license file that keeps the application working. Windows Vista All Versions Activator 2008 Tarp.

Type msconfig and press Enter. Click Tools. Scroll down the list to find and click Change UAC Settings. Press Launch. The User Account Control Settings window will open. Ensure UAC is set to Never notify.